Mô tả ngắn

Hãng sản xuất: Kruss

The manual premium solution for changing contact angle tasks

The Basic configuration of the DSA100 Drop Shape Analyzer combines manual precision measurement of the static contact angle with the technical advantages and robustness of the DSA100 system solution. With fast and simple exchange of solid samples and dosing liquids, the instrument assists you in ensuring the effectiveness of cleaning procedures or the quality of coating and wetting processes. Optional accessories for wetting measurements at higher temperatures and manifold upgrade options enhance the spectrum of the instrument.

HỖ TRỢ NHANH

THÔNG TIN SẢN PHẨM

INSTRUMENT DIMENSIONS

Footprint 555 mm × 375 mm (W × D)
Height 490 mm
Weight (without accessories) 24 kg

TEMPERATURE MEASUREMENT

Range of temperature measurement -50 to 400 °C
Resolution 0.1 °C
Precision 0.1 °C
Accuracy 1/3 DIN B (±0.1 °C at 0 °C to ±0.8 °C at 400 °C)
Location of temperature measurement sample stage
chamber
cuvette
External sensor 2 connectors (PT100)

POWER SUPPLY

Voltage 88 to 264 VAC
Power consumption 100 W
Frequency 50 to 60 Hz

SAMPLE DIMENSIONS

Maximum sample size 320 mm × ∞ × 275 mm (W × D × H) (without axes)
Maximum measuring surface

ENVIRONMENT

Operating temperature 10 to 40 °C
Humidity without condensation

TEMPERATURE CONTROL

Equipment temperature-controlled sample stage
chamber
cuvette
Type of temperature control liquid
electrical
Peltier
Range of temperature control -30 (with Tempering Chamber – TC40) to 400 °C (with Tempering Chamber – TC21)
Maximum sample space 132 mm × 132 mm × 27 mm (W × D × H) (with Tempering Chamber – TC11)
Resolution 0.1 K
Flow-through thermostat with liquid
Inert gas yes

INTERFACES

PC USB 3.0

HOUSING AND PERIPHERALS

Compartment test liquids protected against light
Needle protection shield yes
Camera und optics housing yes
Control keyboard PC keyboard for ADVANCE software operation available (KB20)
Levelling yes

SOFTWARE

Software type ADVANCE
Available software modules contact angle
surface free energy of solids
interfacial and surface tension of liquids
Adhesion Analysis
Remote Control API

SURFACE FREE ENERGY OF SOLIDS

Available optional
Results surface free energy (SFE)
Models equation of state
Zisman
Fowkes
Wu
Owens-Wendt-Rabel-Kaelble
Schultz-1
extended Fowkes
acid-base theory

CAPTIVE BUBBLE

Available included
Results contact angle (CA)
Range 0 to 180° (software-based)
Resolution 0.01° (software-based)
Accuracy 0.1° (instrument-based)
Models conic section
polynom
circle
Young-Laplace
height-width
Type advancing
receding
static
dynamic
tilting
(additional accessories may be required)

SESSILE DROP

Available included
Results contact angle (CA)
Range 0 to 180° (software-based)
Resolution 0.01° (software-based)
Accuracy 0.1° (instrument-based)
Models conic section
polynom
circle
Young-Laplace
height-width
Type advancing
receding
static
dynamic
tilting
(additional accessories may be required)

PENDANT DROP/RISING DROP

Available optional
Results interfacial tension (IFT)/surface tension (SFT)
Range 0.01 to 2000 mN/m (software-based)
Resolution 0.01 mN/m (software-based)
Models Young-Laplace
Types (Pendant drop/Rising drop) static, dynamic

CAMERA SYSTEM (STANDARD)

Type Camera CF04
Connection USB 3.0
Resolution 1920 × 1200 px
Frame rate 2300 fps
Dark noise 7 electrons
Dynamic range 73 dB

ILLUMINATION

Type high power monochromatic LED
Wave length, dominant 470 nm
Field of light 46 mm × 46 mm (D × H)

OPTICS (STANDARD)

Focus manual
Zoom 7× zoom, manual
View angle ±4°
Field of view CF04: 3.9 mm × 3.9 mm to 24.7 mm × 24.7 mm
Resolution of optics CF04: 3.1 to 21.7 μm

CAMERA SYSTEM (OPTIONAL)

Type High Speed Camera CF06
Connection USB 3.0
Resolution 640 × 480 px
Frame rate 3400 fps
Dark noise 10.5 electrons
Dynamic range 56.6 dB

DOSING SYSTEM

Dosing manual
Drop deposition manual
Cartridge/syringe (volume) glass (500 μL), disposable (1 mL)
Resolution
Speed

STAGES

Control x-axis: no (manual or software-controlled optional available)
y-axis: no (manual or software-controlled optional available)
z-axis: manual
Range
Length x-axis: –
y-axis: –
z-axis: 45 mm
Resolution x-axis: –
y-axis: –
z-axis: 16 mm/turn
Accuracy x-axis: –
y-axis: –
z-axis: –

OPTICS (OPTIONAL)

Focus manual
Zoom 7× zoom, manual
View angle ±4°
Field of view CF06: 1.7 mm × 1.3 mm to 10.8 mm × 8.1 mm
Resolution of optics CF06: 2.5 to 17.8 μm

DOUBLE PRESSURE DOSING SYSTEM (OPTIONAL)

Drop deposition software-controlled
Cartridge, volume disposable (1 mL)
Resolution 0.1 μL
Speed fixed

TILTING (OPTIONAL)

Types internal tilting table
external tilting table
Control software-controlled
Range 0 to 90°
Resolution internal: 0.01°
external: 0.1°
Accuracy internal: 0.3°
external: 1°

DOUBLE PRESSURE DOSING SYSTEM

Drop deposition
Cartridge, volume
Resolution
Speed
  • Analyzing wettability of plastics, glass, ceramics, wood, paper, or metal
  • Analyzing the effectiveness of hydrophobic coatings and other coatings
  • Analyzing surface cleanliness
  • Wetting analysis at controlled temperature
  • Contact angle of a drop on a solid surface
  • Contact angle using a gas bubble beneath a solid surface in a liquid
  • Roll-off behavior and advancing/receding contact angle of a drop on a tilted surface
  • Surface tension using the curvature of a perfectly symmetrical drop on a circular sample pedestal
  • Static contact angle
  • Contact angle using a bubble in a liquid
  • Temperature