Mô tả ngắn
Hãng sản xuất: Kruss
The automated premium solution for wetting and adhesion analysis of solids and liquids
The Expert version of the DSA100 Drop Shape Analyzer system solution enables solids and liquids in wetting and coating processes to be analyzed comprehensively. The high degree of automation with easy programmable procedures provides for user-independent contact angle and surface tension results, which is ideal for the use in quality control. However, the DSA100E is also frequently used in R&D due to its versatility in controlling thermal conditions, its dosing solution with four (optional: up to eight) test liquids, and its scientific tools for analyzing the solid/liquid contact.
HỖ TRỢ NHANH
THÔNG TIN SẢN PHẨM
- Specifications
- Applications
- Measuring results
INSTRUMENT DIMENSIONS
Footprint | 555 mm × 375 mm (W × D) |
---|---|
Height | 490 mm |
Weight (without accessories) | 24 kg |
TEMPERATURE MEASUREMENT
Range of temperature measurement | -50 to 400 °C |
---|---|
Resolution | 0.1 °C |
Precision | 0.1 °C |
Accuracy | 1/3 DIN B (±0.1 °C at 0 °C to ±0.8 °C at 400 °C) |
Location of temperature measurement | sample stage chamber cuvette |
External sensor | 2 connectors (PT100) |
POWER SUPPLY
Voltage | 88 to 264 VAC |
---|---|
Power consumption | 100 W |
Frequency | 50 to 60 Hz |
SAMPLE DIMENSIONS
Maximum sample size | 320 mm × ∞ × 275 mm (W × D × H) (without axes) |
---|---|
Maximum measuring surface | – |
ENVIRONMENT
Operating temperature | 10 to 40 °C |
---|---|
Humidity | without condensation |
TEMPERATURE CONTROL
Equipment | temperature-controlled sample stage chamber cuvette |
---|---|
Type of temperature control | liquid electrical Peltier |
Range of temperature control | -30 (with Tempering Chamber – TC40) to 400 °C (with Tempering Chamber – TC21) |
Maximum sample space | 132 mm × 132 mm × 27 mm (W × D × H) (with Tempering Chamber – TC11) |
Resolution | 0.1 K |
Flow-through thermostat | with liquid |
Inert gas | yes |
INTERFACES
PC | USB 3.0 |
---|
HOUSING AND PERIPHERALS
Compartment | test liquids protected against light |
---|---|
Needle protection shield | yes |
Camera und optics housing | yes |
Control keyboard | PC keyboard for ADVANCE software operation available (KB20) |
Levelling | yes |
SOFTWARE
Software type | ADVANCE |
---|---|
Available software modules | contact angle surface free energy of solids interfacial and surface tension of liquids Adhesion Analysis Remote Control API |
SURFACE FREE ENERGY OF SOLIDS
Available | included |
---|---|
Results | surface free energy (SFE) |
Models | equation of state Zisman Fowkes Wu Owens-Wendt-Rabel-Kaelble Schultz-1 extended Fowkes acid-base theory |
CAPTIVE BUBBLE
Available | included |
---|---|
Results | contact angle (CA) |
Range | 0 to 180° (software-based) |
Resolution | 0.01° (software-based) |
Accuracy | 0.1° (instrument-based) |
Models | conic section polynom circle Young-Laplace height-width |
Type | advancing receding static dynamic tilting (additional accessories may be required) |
SESSILE DROP
Available | included |
---|---|
Results | contact angle (CA) |
Range | 0 to 180° (software-based) |
Resolution | 0.01° (software-based) |
Accuracy | 0.1° (instrument-based) |
Models | conic section polynom circle Young-Laplace height-width |
Type | advancing receding static dynamic tilting (additional accessories may be required) |
PENDANT DROP/RISING DROP
Available | included |
---|---|
Results | interfacial tension (IFT)/surface tension (SFT) |
Range | 0.01 to 2000 mN/m (software-based) |
Resolution | 0.01 mN/m (software-based) |
Models | Young-Laplace |
Types (Pendant drop/Rising drop) | static, dynamic |
CAMERA SYSTEM (STANDARD)
Type | Camera CF04 |
---|---|
Connection | USB 3.0 |
Resolution | 1920 × 1200 px |
Frame rate | 2300 fps |
Dark noise | 7 electrons |
Dynamic range | 73 dB |
ILLUMINATION
Type | high power monochromatic LED |
---|---|
Wave length, dominant | 470 nm |
Field of light | 46 mm × 46 mm (D × H) |
OPTICS (STANDARD)
Focus | manual |
---|---|
Zoom | 7× zoom, manual |
View angle | ±4° |
Field of view | CF04: 3.9 mm × 3.9 mm to 24.7 mm × 24.7 mm |
Resolution of optics | CF04: 3.1 to 21.7 μm |
CAMERA SYSTEM (OPTIONAL)
Type | High Speed Camera CF06 |
---|---|
Connection | USB 3.0 |
Resolution | 640 × 480 px |
Frame rate | 3400 fps |
Dark noise | 10.5 electrons |
Dynamic range | 56.6 dB |
DOSING SYSTEM
Dosing | software-controlled (4×) + manual (1×); up to 8 dosing units possible |
---|---|
Drop deposition | software-controlled |
Cartridge/syringe (volume) | glass (450 μL), disposable (3 mL) |
Resolution | 0.1 μL |
Speed | 0.02 to 25 µL/s |
STAGES
Control | x-axis: software-controlled y-axis: software-controlled z-axis: software-controlled |
---|---|
Range | – |
Length | x-axis: 100 mm y-axis: 100 mm z-axis: 38 mm |
Resolution | x-axis: 10 μm y-axis: 10 μm z-axis: 10 μm |
Accuracy | x-axis: 100 μm y-axis: 100 μm z-axis: 100 μm |
OPTICS (OPTIONAL)
Focus | manual |
---|---|
Zoom | 7× zoom, manual |
View angle | ±4° |
Field of view | CF06: 1.7 mm × 1.3 mm to 10.8 mm × 8.1 mm |
Resolution of optics | CF06: 2.5 to 17.8 μm |
DOUBLE PRESSURE DOSING SYSTEM (OPTIONAL)
Drop deposition | software-controlled |
---|---|
Cartridge, volume | disposable (1 mL) |
Resolution | 0.1 μL |
Speed | fixed |
TILTING (OPTIONAL)
Types | internal tilting table external tilting table |
---|---|
Control | software-controlled |
Range | 0 to 90° |
Resolution | internal: 0.01° external: 0.1° |
Accuracy | internal: 0.3° external: 1° |
DOUBLE PRESSURE DOSING SYSTEM
Drop deposition | – |
---|---|
Cartridge, volume | – |
Resolution | – |
Speed | – |
- Quality assurance and optimization of activation processes such as plasma treatment, flame treatment, or corona treatment before coating or bonding
- Analyzing the wettability of plastics, glass, ceramics, wood, paper, or metal
- Analyzing the effectiveness of hydrophobic coatings and other coatings
- Analyzing coating liquids and adhesives and assessing their adhesion
- Assessing long-term stability of coatings
- Analyzing (super-) hydrophobic and self-cleaning surfaces
- Analyzing homogeneity of cleanliness and wettability and measuring differences between coated/uncoated or treated/untreated areas
- Wetting analysis at controlled temperature and/or humidity
- Measuring surface tension of hot liquids, e.g. hotmelts
- Static contact angle
- Advancing and receding contact angle
- Contact angle using a bubble in a liquid
- Roll-off angle
- Surface free energy (SFE) according to the following models: Owens-Wendt-Rabel-Kaelble (OWRK), Fowkes, Extended Fowkes, Van Oss & Good (Acid-Base), Schultz, Wu, Zisman, Equation of State
- Position-dependent contact angle and SFE
- Surface tension of a liquid and interfacial tension between two liquids
- Work of adhesion, solid/liquid interfacial tension, spreading coefficient
- Temperature