Mô tả ngắn
Hãng sản xuất: Kruss
Measuring foam formation and decay speed for quality control – reliably and reproducibly
Foam is a welcome companion to many products, but almost as often it is a nuisance that must to be avoided. Either way, for quality control of your products and processes, it is necessary to exactly determine the foaming behavior of the liquids and foam-inhibiting additives involved. The easy-to-use Foam Tester – FT carries out this task reliably and in an exactly repeatable manner. Using accurately controlled gas flow and precise electronic foam height measurement, the Foam Tester gives you significant results for the foaming capacity of your liquid and the decay speed of the resulting foam.
HỖ TRỢ NHANH
THÔNG TIN SẢN PHẨM
- Specifications
- Applications
- Measuring Methods
- Measuring Results
INSTRUMENT DIMENSIONS
Footprint | 245 mm × 275 mm (W × D) |
---|---|
Height | 460 mm |
Weight (without accessories) | 9 kg |
TEMPERATURE MEASUREMENT
Sensor | PT100 |
---|---|
Range of temperature measurement | 4 to 90 °C |
Resolution | 0.1 °C |
Precision | 0.1 °C |
Accuracy | 1/3 DIN B (±0.1 °C at 0 °C, ±0.8 °C at 400 °C) |
Location of temperature measurement | inside sample liquid |
External sensor | – |
POWER SUPPLY
Voltage | 100 to 240 VAC |
---|---|
Power consumption | maximum 30 W |
Frequency | 50 to 60 Hz |
SAMPLE DIMENSIONS
Min. recommended sample volume | 50 mL with 40 mm diameter column |
---|
ENVIRONMENT
Operating temperature | 15 to 30 °C |
---|---|
Humidity | without condensation |
TEMPERATURE CONTROL
Type of temperature control | double-walled glass column |
---|---|
Range of temperature control | 4 to 90 °C (additional thermostat needed: TB14) |
Resolution | 0.1 °C |
INTERFACES
PC | 1× USB 2.0 |
---|
ACCESSORIES
Glass columns | 40 mm diameter, temperature control option |
---|---|
Filter plates for sparging | – |
Filter plate porosities | – |
Material of columns and frits | – |
Material of columns and filters | column: borosilicate glass, norm: ISO 4793, filter paper: cellulose |
Material of sealings | silicone and FKM |
Receiver | – |
PRESSURE MEASUREMENT
Precision | – |
---|
SAMPLE STAGE
Travel distance | – |
---|
DRIVE
DATA OUTPUT
CAMERA SYSTEM
Diameter of minimum detectable bubble | – |
---|---|
Mean field of view size | – |
Focus | – |
LINE SENSOR
Maximum measurable height | – |
---|---|
Sensor resolution | 1728 × 1 px |
Spatial resolution | 200 dpi | 0.125 mm |
Temporal resolution | 5 fps |
Scanning length | 216 mm |
OPERATING SYSTEM
Internal gas flow rate | 0.2 to 1.0 L/min |
---|---|
External gas flow rate | 0.05 to 1.0 L/min |
Approved gases | air nitrogen carbon dioxide |
Approved pressure | 5 ± 0.5 bar |
Approved temperature | 4 to 90 °C |
Stirring speed | – |
CAMERA SYSTEM (STANDARD)
Connection | – |
---|---|
Performance | – |
ELECTRODES
Material | – |
---|---|
Highest sensor position | – |
Measured entity | – |
Theoretical measurement range | – |
ILLUMINATION
Type | LED |
---|---|
Wave length, dominant | 469 nm (IR: 850 nm) |
Wave length, dominant (height detection) | – |
SOFTWARE
Software type | ADVANCE |
---|---|
Available software modules | foam analysis |
BUBBLE PRESSURE
Precision (surface tension) | – |
---|
MEASUREMENT SPECIFICATIONS
Measurement type | – |
---|---|
Analyzed foam characteristic | foamability and foam stability |
Foaming | – |
Resolution | – |
Results | foam height liquid height total height foam capacity foam half life time drainage half life time sample temperature |
- Foam-inhibiting and foam-reducing agents (anti-foaming agents/defoamers)
- Foam prevention for paints and varnishes, process and waste water, or cooling lubricants
- Foams for washing and cleaning
- Foams in food and personal care products
- Firefighting foams
- Flotation as a method for separating solids
- Foamability and foam stability using the optically detected height of foam created reproducibly
- Carrying out a measurement up to 20 consecutive times and displaying the results together
- Maximum foam volume and height
- Foam capacity
- Decay curves: total height and volume as well as foam and liquid height and volume at each measured point in time
- Time values for the reduction of liquid volume in foam and foam volume to 50% (foam half-life)
- Sample temperature