Mô tả ngắn
Hãng sản xuất: Kruss
Time-dependent analysis of bubble size in liquid foams
The FSM Foam Structure Module for the DFA100 captures the bubble size and size distribution of foam using intelligent video image analysis. The results help you to produce foam with the shape you want it to have. They also show the decay of long-lasting foam, long before it actually collapses, thus supporting you in optimizing foam stability.
HỖ TRỢ NHANH
THÔNG TIN SẢN PHẨM
- Specifications
- Accessories
- Applications
INSTRUMENT DIMENSIONS
Footprint | 245 mm × 275 mm (W × D) |
---|---|
Height | 460 mm |
Weight (without accessories) | 13 kg |
TEMPERATURE MEASUREMENT
Sensor | PT100 |
---|---|
Range of temperature measurement | 4 to 90 °C |
Resolution | 0.1 °C |
Precision | 0.1 °C |
Accuracy | 1/3 DIN B (±0.1 °C at 0 °C / ±0.8 °C at 400 °C) |
Location of temperature measurement | inside sample liquid |
External sensor | optional |
POWER SUPPLY
Voltage | 100 to 240 V |
---|---|
Power consumption | 30 W |
Frequency | 50 to 60 Hz |
SAMPLE DIMENSIONS
Min. recommended sample volume | 50 mL with 40 mm diameter column |
---|
ENVIRONMENT
Operating temperature | 15 to 30 °C |
---|---|
Humidity | without condensation |
TEMPERATURE CONTROL
Type of temperature control | optional: double-walled glass column |
---|---|
Range of temperature control | 10 to 60 °C (additional thermostat needed: TB14) |
Resolution | – |
INTERFACES
PC | 1× USB 2.0 1× USB 3.0 |
---|
ACCESSORIES
Glass columns | 40 mm diameter, temperature control option |
---|---|
Filter plates for sparging | diameter: 30 mm |
Filter plate porosities | G1: nominal maximum pore size: 100 to 160 μm G2: nominal maximum pore size: 40 to 100 μm G3: nominal maximum pore size: 16 to 40 μm G4: nominal maximum pore size: 10 to 16 μm |
Material of columns and frits | borosilicate glass (norm: ISO 4793) |
Material of columns and filters | – |
Material of sealings | silicone and FKM |
Receiver | – |
PRESSURE MEASUREMENT
Precision | ADVANCE |
---|
SAMPLE STAGE
Travel distance | 0.1 °C |
---|
DRIVE
DATA OUTPUT
CAMERA SYSTEM
Diameter of minimum detectable bubble | 50 µm |
---|---|
Mean field of view size | position 1: 285 mm2 position 2: 140 mm2 position 3: 85 mm2 |
Focus | manual |
LINE SENSOR
Maximum measurable height | – |
---|---|
Sensor resolution | 1728×1px |
Spatial resolution | 200 dpi | 0.125 mm |
Temporal resolution | 20 fps |
Scanning length | 216 mm |
OPERATING SYSTEM
Internal gas flow rate | 0.2 to 1 L/min |
---|---|
External gas flow rate | 0.05 to 1 L/min |
Approved gases | air nitrogen carbon dioxide |
Approved pressure | 5 ± 0.5 bar |
Approved temperature | 4 to 90 °C |
Stirring speed | up to 8000 rpm |
CAMERA SYSTEM (STANDARD)
Connection | USB 3.0 |
---|---|
Performance | 2 fps at 1280 × 1024 px |
ELECTRODES
Material | – |
---|---|
Highest sensor position | – |
Measured entity | – |
Theoretical measurement range | – |
ILLUMINATION
Type | LED |
---|---|
Wave length, dominant | – |
Wave length, dominant (height detection) | 469 nm (optional IR: 850 nm) |
Wave length, dominant (structure detection) | 633 nm |
SOFTWARE
Software type | ADVANCE |
---|---|
Available software modules | foam analysis |
BUBBLE PRESSURE
Precision (surface tension) | 15 to 30 °C |
---|
MEASUREMENT SPECIFICATIONS
Measurement type | – |
---|---|
Analyzed foam characteristic | foamability and foam stability foam structure: homogeneity, stability and aging |
Foaming | – |
Resolution | – |
Results | foam height liquid height total height foam capacity maximum foam density expansion rate foam half life time drainage half life time sample temperature mean bubble area bubble count per mm² standard deviation of mean bubble area bu |
Prism column with reference grid for foam structure analyses
Short prism column for structure analyses with any foaming method
Sealing rings for different foaming methods and liquids (for sample holder predecessor models)
Sealing rings for different foaming methods and liquids (for sample holder predecessor models)
Sealing rings for different foaming methods and liquids (for sample holder predecessor models)
Sealing rings for different foaming methods and liquids (for sample holder predecessor models)
Sealing rings for different foaming methods and liquids (for sample holder predecessor models)
Sealing rings for different foaming methods and liquids
Sealing rings for different foaming methods and liquids
Sealing rings for different foaming methods and liquids
- Foams for washing and cleaning
- Foams in food and personal care products
- Surfactant development
- Flotation as a method for separating solids