Dynamic Foam Analyzer DFA100
Mô tả ngắn
Hãng sản xuất: Kruss
The universal instrument for all aspects of liquid foam.
Many questions about foam, one universal approach: The DFA100 Dynamic Foam Analyzer measures the foamability of liquids and the stability of quickly decaying or long lasting foam based on reproducible foaming and height detection. With optional modules operating in parallel, it also measures the liquid content or analyzes the foam structure with regard to bubble size and distribution. The DFA100 supports you in optimizing foam-forming products or helps you to avoid unwanted foam formation.
HỖ TRỢ NHANH
THÔNG TIN SẢN PHẨM
- Specifications
- Accessories
- Applications
INSTRUMENT DIMENSIONS
Footprint | 245 mm × 275 mm (W × D) |
---|---|
Height | 460 mm |
Weight (without accessories) | 9 kg |
TEMPERATURE MEASUREMENT
Sensor | PT100 |
---|---|
Range of temperature measurement | 4 to 90 °C |
Resolution | 0.1 °C |
Precision | 0.1 °C |
Accuracy | 1/3 DIN B (±0.1 °C at 0 °C / ±0.8 °C at 400 °C) |
Location of temperature measurement | inside sample liquid |
External sensor | optional |
POWER SUPPLY
Voltage | 100 to 240 V |
---|---|
Power consumption | 30 W |
Frequency | 50 to 60 Hz |
SAMPLE DIMENSIONS
Min. recommended sample volume | 50 mL with 40 mm diameter column optional: 20 mL with 20 mm diameter column |
---|
ENVIRONMENT
Operating temperature | 15 to 30 °C |
---|---|
Humidity | without condensation |
TEMPERATURE CONTROL
Type of temperature control | optional: double-walled glass column |
---|---|
Range of temperature control | 4 to 90 °C (additional thermostat needed: TB14) |
Resolution | – |
INTERFACES
PC | 1× USB 2.0 |
---|
ACCESSORIES
Glass columns | 20 and 40 mm diameter, temperature control option |
---|---|
Filter plates for sparging | diameter: 14 and 30 mm |
Filter plate porosities | G1: nominal maximum pore size: 100 to 160 μm G2: nominal maximum pore size: 40 to 100 μm G3: nominal maximum pore size: 16 to 40 μm G4: nominal maximum pore size: 10 to 16 μm |
Material of columns and frits | borosilicate glass (norm: ISO 4793) |
Material of columns and filters | – |
Material of sealings | silicone and FKM |
Receiver | – |
PRESSURE MEASUREMENT
Precision | – |
---|
SAMPLE STAGE
Travel distance | – |
---|
DRIVE
DATA OUTPUT
CAMERA SYSTEM
Diameter of minimum detectable bubble | – |
---|---|
Mean field of view size | – |
Focus | – |
LINE SENSOR
Maximum measurable height | – |
---|---|
Sensor resolution | 1728×1px |
Spatial resolution | 200 dpi | 0.125 mm |
Temporal resolution | 20 fps |
Scanning length | 216 mm |
OPERATING SYSTEM
Internal gas flow rate | 0.2 to 1 L/min |
---|---|
External gas flow rate | 0.05 to 1 L/min |
Approved gases | air nitrogen carbon dioxide |
Approved pressure | 5 ± 0.5 bar |
Approved temperature | 4 to 90 °C |
Stirring speed | up to 8000 rpm |
CAMERA SYSTEM (STANDARD)
Connection | – |
---|---|
Performance | – |
ELECTRODES
Material | – |
---|---|
Highest sensor position | – |
Measured entity | – |
Theoretical measurement range | – |
ILLUMINATION
Type | LED |
---|---|
Wave length, dominant | – |
Wave length, dominant (height detection) | 469 nm (optional IR: 850 nm) |
SOFTWARE
Software type | ADVANCE |
---|---|
Available software modules | foam analysis |
BUBBLE PRESSURE
Precision (surface tension) | – |
---|
MEASUREMENT SPECIFICATIONS
Measurement type | – |
---|---|
Analyzed foam characteristic | foamability and foam stability |
Foaming | – |
Resolution | – |
Results | foam height liquid height total height foam capacity maximum foam density expansion rate foam half life time drainage half life time sample temperature |
PENETRATION
- Firefighting foams
- Flotation as a method for separating solids
- Foam prevention for paints and varnishes, process and waste water, or cooling lubricants
- Foam-inhibiting and foam-reducing agents (anti-foaming agents/defoamers)
- Foams for washing and cleaning
- Foams in food and personal care products
- Surfactant development